SLM 6/3 - STERILE AIR MODULE

STERILSYSTEMS

If you are interested in this product, you can contact us

Contact us

PRODUCT DESCRIPTION:

The SLM6/3 is used to sterilize the airless area of tanks or containers and to sterilize intake air. The SLM6/3 is used to guide air through three filter stages (G4, F7, H13) for treatment and filtration. Then the air is sterilized by the UV-C module, after which it is blown into the existing tank.

Filtering and UV-C disinfection are combined into just one device, allowing for the reliable elimination of dust particles, suspended and polluting materials and microorganisms ; dry, heat-free and chemical-free disinfection

Applications: Ventilation systems | Ventilation ducts | Airless areas of tanks/containers

Equipment: Module contains three filter stages (G4, F7, H13) and the UV-C module; UV-C emitters are waterproof with a protective glass; switch cabinet contains operating hours counter and remote signaling contact for functional monitoring.

Assembly/maintenance: The module is mounted upstream of the suction channel; maintenance can easily be performed on the filter and emitter from the outside


The SLM6/3 is used to sterilize the airless area of tanks or containers and to sterilize intake air. The SLM6/3 is used to guide air through three filter stages (G4, F7, H13) for treatment and filtration. Then the air is sterilized by the UV-C module, after which it is blown into the existing tank.

Filtering and UV-C disinfection are combined into just one device, allowing for the reliable elimination of dust particles, suspended and polluting materials and microorganisms ; dry, heat-free and chemical-free disinfection

Applications: Ventilation systems | Ventilation ducts | Airless areas of tanks/containers

Equipment: Module contains three filter stages (G4, F7, H13) and the UV-C module; UV-C emitters are waterproof with a protective glass; switch cabinet contains operating hours counter and remote signaling contact for functional monitoring.

Assembly/maintenance: The module is mounted upstream of the suction channel; maintenance can easily be performed on the filter and emitter from the outside

Type

SLM6/3

Dimensions in mm L x W x H

1830mm × 713mm × 435mm

Housing material

Galvanized steel or stainless steel

Emitter ST1

UV-C high efficiency / 16.000 h

Power in W

300 W

Voltage

230V ± 10% (50 – 60Hz)

Connection cable in m

3m / 6m / 10m

Weight in kg

70 kg

Protection class

IP 68

Filter stage 1

Filter class G4 as per EN779:2012

Average degree of separation (Am) of the synthetic test dust (%) G4: 90 ≤ Am

Filter stage 2

Filter class F9 as per EN 779:2012

Minimum effectiveness at 0.4 μm F9 70%, mean effectiveness (Em) of 0.4 μm 95 ≤ Em

Filter stage 3

Filter class H13 as per EN 1822 aerosol filter